<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>23327</ErrorNumber>
<ErrorFamily>Satellite</ErrorFamily>
<ErrorMessage>
SCON: Stepper Motor %u driver under voltage fault detected
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check voltage in on 48V on J1-1 &amp; J1-2, +12V in on J1-5, and -12V in
on J1-4.  The status is on TP6 (high=fault low=ok).  You can read the
24 and 48 V as read by each genine by typing 'ale'.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
</text></DescriptionText>
</OperatorAction>
<Cause>
Remote stepper driver under voltage fault was detected.  The under voltage
fault signal is the combination of +12 low, or -12 low or the 48 V low,
as read by on the Carriage board (10-3761B) and passed as a digital status
signal to the Genine.
Variable:     &lt;%u&gt; - motor number
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:12 2008 PST
</Updated>
<Links>
</Links>
</Error>